CC-AA-112 — Temporary Configuration Changes
Purpose
Administrative procedure governing the process for controlling temporary design/configuration changes at Salem and Hope Creek stations.
Key Requirements
- CRS is responsible for approving installation of Temporary Configuration Changes (TCCs)
- Design Engineering Manager is an approver in the development of the TCCP but does not approve installation
- TCCs established during maintenance activity (MR90s) are not subject to a 50.59 review provided:
- The MR90 is in direct support of maintenance
- The MR90 will be installed for no more than 90 days at power
- TCCs installed greater than 90 days require a 50.59 review
Exam History
- 2022 Q96 — Temporary Configuration Changes: CRS approval authority and 90-day 50.59 threshold
Connections
- Related exam: 2022 NRC Written Exam