admin > SC.RE-ST.ZZ-0002 — Shutdown Margin Calculation

SC.RE-ST.ZZ-0002 — Shutdown Margin Calculation

⚠️ DRAFT

SC.RE-ST.ZZ-0002 — Shutdown Margin Calculation

Purpose

Surveillance procedure for calculating shutdown margin (SDM) to verify compliance with TS 3.1.1.1. Used to verify SDM when required by tech spec action statements (e.g., TSAS 3.1.3.1 Action c.3 for inoperable/misaligned rods) and for periodic SDM verification.

Key Steps

Step 5.1 — Select applicable attachment:

  • 5.1.1.A: SDM in Modes 3, 4, and 5
  • 5.1.1.C: SDM verification with reactor critical (Mode 1 or 2) and one or more control rods inoperable — uses Attachment 3

Attachment 3 — SDM with Reactor Critical and Inoperable Rod(s):

SectionContentKey Input
4.1Critical ConditionsPower level, boron concentration, bank position, burnup, number of untrippable rods, number of inoperable rods
4.2Calculation of Rod WorthTotal rod worth from tables/figures in S2.RE-RA.ZZ-0016 Curve Book
4.3Calculation of SDMCombines rod worth with defects (temperature, Doppler, etc.)
4.4Acceptance CriteriaSDM must be equal to or more negative than -1300 pcm in Modes 1 or 2

References: S2.RE-RA.ZZ-0016 Curve Book provides rod worth tables and figures.

JPM — 2020 RO-A1
SDM calculation with one inoperable (but trippable) rod (1D5 at 214 steps): Step 4.2.6 rod bank penalty is based on the position of the rod BANK (225 steps = ARO), NOT the individual misaligned rod. Since bank is at ARO, penalty = 0 pcm. Step 4.1.5 = 0 untrippable rods (1D5 is trippable). Step 4.1.6 = 1 inoperable rod. Calculated SDM = -2398 pcm, which is more negative than acceptance criteria of -1300 pcm — SDM is SAT. Time critical: 60-minute limit.