SALEM
SALEM STUDY SYSTEM
procedures > S1.OP-SO.SF-0001 — Fill and Transfer of Spent Fuel Pool

S1.OP-SO.SF-0001 — Fill and Transfer of Spent Fuel Pool

⚠️ DRAFT

S1.OP-SO.SF-0001 — Fill and Transfer of Spent Fuel Pool

Purpose

Provides direction for filling and transferring water to/from the Spent Fuel Pool, including preferred makeup water sources.

Key Actions / Information

Exam — 2022 Q61
Prerequisite step 2.3 specifies the preferred order of SFP makeup water sources: 1) Demineralized Water, 2) Primary Water, 3) CVCS Holdup Tanks, 4) RWST or Refueling Cavity. The RWST is the least preferred source of makeup water to the SFP.

Connections