S1.OP-SO.SF-0001 — Fill and Transfer of Spent Fuel Pool
Purpose
Provides direction for filling and transferring water to/from the Spent Fuel Pool, including preferred makeup water sources.
Key Actions / Information
Exam — 2022 Q61
Prerequisite step 2.3 specifies the preferred order of SFP makeup water sources: 1) Demineralized Water, 2) Primary Water, 3) CVCS Holdup Tanks, 4) RWST or Refueling Cavity. The RWST is the least preferred source of makeup water to the SFP.
Connections
- Related systems: Spent Fuel Pool
- Related exam questions: 2022 Q61