procedures > S2.OP-SO.SW-0005 — Service Water System Operation

S2.OP-SO.SW-0005 — Service Water System Operation

⚠️ DRAFT

S2.OP-SO.SW-0005 — Service Water System Operation

Purpose

Provides operating procedures for the Unit 2 Service Water System, including pump operations, bay configurations, and precautions and limitations related to SW loop operability.

Key Actions / Information

Exam — 2020 Q14
P&L 3.2 states: "When a Service Water Bay is removed from service in Modes 1-4, and the Service Water Pump fed from 'B' bus in the OPERABLE Service Water Bay is unavailable (23 or 24 SWP), then L.C.O 3.0.3 is applicable." An OPERABLE SW loop consists of two service water pumps powered from separate buses. With #2 SW Bay isolated (leak) and 24 SWP C/Ted, both SW loops are inoperable — TS 3.0.3 applies.