Purpose

Surveillance procedure for monitoring Axial Flux Difference (AFD) on Salem Unit 2 per TS 3.2.1 requirements. Covers both the 7-day AFD surveillance (Section 4.1) and the manual AFD calculation when the AFD Monitor alarm is inoperable (Section 5.3).

Key Actions / Information

Section 5.3 — Manual AFD Calculation (when AFD Monitor is inoperable):

Per Section 5.3 and Attachment 3 (AFD Data Log Sheet):

  • Step 5.3.1.A: ENTER present Reactor Power
  • Step 5.3.1.B: ENTER AFD Target from REM Table 3
  • Step 5.3.1.C: CALCULATE AFD Target for present power level = (Present Power / 100) x AFD Target; round to first decimal place per P&L 3.2
  • Step 5.3.1.D: DETERMINE Upper and Lower Limits by adding the AFD Target value to the Target Band limits from REM Table 3 (NOTE: use the more restrictive of COLR or REM limits)
  • Step 5.3.1.E: ENTER AFD Channel Readings (Channels I-IV)
  • Step 5.3.1.F: DETERMINE if channels are within the Target Band and notify CRS of results
JPM — 2023 RO-A2
Seven Day AFD surveillance (Section 4.1) at 73% power: AFD Target = -2.0, Target Offset = +0.5, Corrected AFD Target = -1.5. Upper Limit = +6.0 + (-1.5) = +4.5. Lower Limit = -10.0 + (-1.5) = -11.5. Channel III reading of -10.6 found outside the AFD lower limit — surveillance UNSAT.
JPM — 2018 RO-A1
Manual AFD calculation (Section 5.3) at 73% power with AFD Monitor alarm inoperable: AFD Target from REM Table 3 = -1.5. Calculated AFD Target = (73/100) x (-1.5) = -1.095, rounded to -1.1 per P&L 3.2. Upper Limit = +6.0 + (-1.1) = +4.9. Lower Limit = -9.0 + (-1.1) = -10.1. Channels III (-10.3) and IV (-10.5) are outside the AFD Lower Limit of -10.1. With two channels outside the target band, TS action is required.