SALEM
SALEM STUDY SYSTEM
Exams > 2018 JPM RO-A1 — Perform a Manual AFD Calculation

2018 JPM RO-A1 — Perform a Manual AFD Calculation

⚠️ DRAFT
JPM RO-A1 — Perform a Manual AFD Calculation Admin | RO/SRO | G2.1.25 (3.9)
Location: Classroom
Time-Critical: No
Alternate Path: No
Estimated Time: 10 minutes

Initial Conditions:
- Salem Unit 2 completed a down power to 73% power today at 0830 IAW TSAS 3.1.3.1.c.3.d due to a single control rod being declared inoperable.
- The AFD Monitor Alarm for the Auxiliary Annunciator was determined to be inoperable at 0840.

Initiating Cue:
- You are the Reactor Operator.
- The CRS directs you to perform a manual AFD calculation IAW Section 5.3 of S2.OP-ST.NIS-0001 (Q), Power Distribution — Axial Flux Difference.
- Current AFD Channel Console Readings are:
  Channel I: -9.8
  Channel II: -9.7
  Channel III: -10.3
  Channel IV: -10.5
- All prerequisites are completed SAT.
- NOTIFY the CRS of the results of the surveillance after completing Step 5.3.1.F.
Task Standard:
1. Completes applicable portion of Attachment 3 of S2.OP-ST.NIS-0001, and determines Channel III and IV are operating outside the AFD Target Band.
▶ Show Critical Steps & Key Actions
Step Critical Element Standard
5.3.1 IF AFD Monitor (XA-8740) OR Monitor Alarm (Auxiliary Annunciator) is inoperable, THEN COMPLETE Attachment 3 Operator uses Attachment 3 to determine AFD.
5.3.1.A ENTER present Reactor Power Operator enters 73% power.
5.3.1.B ENTER AFD Target from S2.RE-RA.ZZ-0011, Tables, Table 3 Operator enters (-1.5) for AFD Target using the Salem 2 Cycle 23 REM, Table 3.
5.3.1.C * CALCULATE the AFD Target value IAW (Present Power / 100) x (AFD Target) Calculates AFD Target for present power level: (73/100) x (-1.5) = -1.095. IAW P&L 3.2, round to first decimal place = -1.1.
5.3.1.D * DETERMINE Upper and Lower Limits using Target Band values from REM Table 3 Upper Limit: +6.0 + (-1.1) = +4.9. Lower Limit: -9.0 + (-1.1) = -10.1.
5.3.1.E ENTER AFD Channel Readings Enters AFD values from initial conditions on Attachment 3: Ch I: -9.8, Ch II: -9.7, Ch III: -10.3, Ch IV: -10.5.
5.3.1.F * DETERMINE channels within/outside AFD Target Band and notify CRS Determines Channels III (-10.3) and IV (-10.5) are operating outside the Lower Target Band limit of -10.1. Notifies CRS of results.
Key Decision Point:
Step 5.3.1.F is the discriminating step. After calculating the AFD Target (-1.1) and determining the Lower Limit (-10.1), the applicant must compare each channel reading against the limits. Channels I (-9.8) and II (-9.7) are within the band. Channels III (-10.3) and IV (-10.5) are MORE NEGATIVE than the Lower Limit of -10.1, placing them outside the target band. With two AFD channels outside the target band, TS action is required to reduce reactor power.
Ref: S2.OP-ST.NIS-0001 (Rev 13), Salem 2 Cycle 23 REM (Rev 17), Salem Unit 2 COLR Cycle 23 (Rev 7) | Task: N0150010201 | K/A: G2.1.25 — Ability to interpret reference materials, such as graphs, curves, tables, etc. | Source: New | View JPM PDF