JPM RO-A4 — Activate ERDS IAW EP-SA-111-F8
Admin | RO/SRO | G2.4.43 (3.2)
Location: Simulator / Perform
Time-Critical: No
Alternate Path: No
Estimated Time: 5 minutes
Initial Conditions:
- Salem Unit 2 was manually tripped from 100% power due to an RCS leak.
- Safety Injection was manually initiated and all ECCS pumps are running.
- The Shift Manager has declared an ALERT.
Initiating Cue:
- You are the Work Control NCO and designated Secondary Communicator.
- ACTIVATE ERDS IAW Step 1.2.b of EP-SA-111-F8, Secondary Communicator Log.
- Notify the Shift Manager when ERDS is activated.
Time-Critical: No
Alternate Path: No
Estimated Time: 5 minutes
Initial Conditions:
- Salem Unit 2 was manually tripped from 100% power due to an RCS leak.
- Safety Injection was manually initiated and all ECCS pumps are running.
- The Shift Manager has declared an ALERT.
Initiating Cue:
- You are the Work Control NCO and designated Secondary Communicator.
- ACTIVATE ERDS IAW Step 1.2.b of EP-SA-111-F8, Secondary Communicator Log.
- Notify the Shift Manager when ERDS is activated.
Task Standard:
Activates ERDS IAW EP-SA-111-F8.
Activates ERDS IAW EP-SA-111-F8.
▶ Show Critical Steps & Key Actions
| Step | Critical Element | Standard |
|---|---|---|
| 1.2.b | Within 60 minutes, ACTIVATE ERDS from a LAN computer | Operator proceeds to ERDS XXX computer located inside Salem Simulator horseshoe area. |
| 1.2.b.1 * | PROCEED to a computer labeled "ERDS XXX" and START the program by SELECTING the ERDS_Salem desktop icon | Operator selects the ERDS_Salem desktop icon. |
| 1.2.b.2 * | On the "Login For ERDS Display" popup window ENTER the PASSWORD and SELECT "Login" to proceed | Operator enters the PASSWORD and selects "Login" to proceed. |
| 1.2.b.3 * | SELECT the Action button labeled <CONNECT> for Salem 2 "ERDS Link Control and Status Display Screen" | Operator selects the button labeled <CONNECT> for Salem 2 "ERDS Link Control and Status Display Screen". |
| 1.2.b.4 * | SELECT the <YES> button in the "Current Link Control State is Disconnect. Do You Want To Connect?" box | Operator selects <YES> button in the confirmation dialog. |
| 1.2.b.5 * | OBSERVE that Status changes to "Transmitting Data" | Operator checks that the Status changes to "Transmitting Data". |
| 1.2.b.6 * | VERIFY successful communications status by observing that the "Messages Sent" value is increasing from zero "0" to some positive integer > "0" | Operator verifies that the "Messages Sent" value is increasing from zero "0" to some positive integer > "0". |
| 1.2.b.7 | INFORM the CRS of successful ERDS activation status | Notifies CRS/SM that ERDS is activated. |
Key Decision Point:
Step 1.2.b.3 is the discriminating step — the applicant must select the correct unit (Salem 2) ERDS Link Control and Status Display Screen, since the initial conditions state Unit 2 experienced the manual trip and RCS leak. Selecting Salem 1 would be an incorrect action. This same discriminating step appears in the 2020 and 2023 ERDS activation JPMs.
Step 1.2.b.3 is the discriminating step — the applicant must select the correct unit (Salem 2) ERDS Link Control and Status Display Screen, since the initial conditions state Unit 2 experienced the manual trip and RCS leak. Selecting Salem 1 would be an incorrect action. This same discriminating step appears in the 2020 and 2023 ERDS activation JPMs.
Ref: EP-SA-111-F8 (Rev 6) | Task: N1240110501 | K/A: G2.4.43 — Knowledge of emergency communications systems and techniques | Source: New | View JPM PDF