Q33 — SFP Routine Makeup Water Sources
033 SFPCS-K4.01 (2.9)
Given the following Salem Water Sources:
1. Demineralized Water System
2. Primary Water Storage Tank
3. CVCS Holdup Tanks
4. Refueling Water Storage Tank
5. Fresh Water and Fire Protection Water Storage Tank
Which ONE of the following completes the statements below concerning Unit 2 Spent Fuel Pool?
In accordance with S2.OP-SO.SF-0001 (Fill And Transfer Of The Spent Fuel Pool), ___ are sources of water that can be used to provide ROUTINE makeup to the Spent Fuel Pool.
1. Demineralized Water System
2. Primary Water Storage Tank
3. CVCS Holdup Tanks
4. Refueling Water Storage Tank
5. Fresh Water and Fire Protection Water Storage Tank
Which ONE of the following completes the statements below concerning Unit 2 Spent Fuel Pool?
In accordance with S2.OP-SO.SF-0001 (Fill And Transfer Of The Spent Fuel Pool), ___ are sources of water that can be used to provide ROUTINE makeup to the Spent Fuel Pool.
A. 1, 2, 3, and 4 ONLY
B. 2, 3, and 4 ONLY
C. 3, 4, and 5 ONLY
D. 1, 2, 3, 4, and 5
▶ Show Answer & Explanation
✓ A. Correct. In accordance with S2.OP-SO.SF-0001 (Fill And Transfer Of The Spent Fuel Pool), the following water sources are allowed to be used for ROUTINE makeup to the Spent Fuel Pool: 1) Demineralized Water System, 2) Primary Water Storage Tank, 3) CVCS Holdup Tanks, 4) Refueling Water Storage Tank. The Fresh Water and Fire Protection Water Storage Tank is NOT an allowed ROUTINE makeup source.
✗ B. All of the listed water sources are actual Salem Water Sources. Consequently, all of the distractors are plausible when determining the allowed ROUTINE makeup sources to the Spent Fuel Pool.
✗ C. All of the listed water sources are actual Salem Water Sources. Consequently, all of the distractors are plausible when determining the allowed ROUTINE makeup sources to the Spent Fuel Pool.
✗ D. All of the listed water sources are actual Salem Water Sources. Consequently, all of the distractors are plausible when determining the allowed ROUTINE makeup sources to the Spent Fuel Pool.
Ref: NOS05SFP000-10 (Spent Fuel Pool Cooling System) | LO: NOS05SFP000-10 Obj 11 — Discuss procedural requirements associated with the SFP Cooling System | Source: New | Cognitive: Lower
Connections
- Related systems: Spent Fuel Pool, CVCS, Demin Water
- Related procedures: S2.OP-SO.SF-0001 — Fill and Transfer of Spent Fuel Pool
- Related exam: 2018 NRC Written Exam