Exams > 2019 JPM RO-A1 — Determine Maximum Vent Time in EOP-FRCI-3

2019 JPM RO-A1 — Determine Maximum Vent Time in EOP-FRCI-3

⚠️ DRAFT
JPM RO-A1 — Determine Maximum Vent Time in EOP-FRCI-3 Admin | RO/SRO | G2.1.25 (3.9)
Location: Classroom
Time-Critical: No
Alternate Path: No
Estimated Time: 8 minutes

Initial Conditions:
- Unit 2 has experienced a small break LOCA.
- The crew has performed an RCS cooldown and depressurization in EOP-LOCA-2.
- During the depressurization the crew experienced some complications and indications of upper head voiding are now present.
- STA reports a valid CFST YELLOW path exists on Coolant Inventory.
- The TSC recommends initiating EOP-FRCI-3, Response to Void in Reactor Vessel.

Initiating Cue:
- You are the extra NCO.
- The crew has completed actions in EOP-FRCI-3 up to step 19.1 and has directed you to PERFORM Attachment 1 of EOP-FRCI-3 to determine the maximum venting time.
- The following conditions exist in Unit 2 containment:
  - Containment temperature is 140 F
  - Containment hydrogen concentration is 1.8%
  - RCS pressure is 1200 psig
- Round off to the nearest tenths when performing your calculations
Task Standard:
1. Correctly performs calculations IAW EOP-FRCI-3, Attachment 1.
2. Calculates Maximum Venting Time of 10.2 mins (9.2 - 11.2 mins acceptable band).
▶ Show Critical Steps & Key Actions
Step Critical Element Standard
1 Record data from initial conditions (containment temp, H2 concentration, RCS pressure) Records provided data in steps 1.1 through 1.3
2.1 * Calculate containment absolute temperature (Tabs) Tabs = 140 + 460 = 600 R
2.2 * Calculate containment air volume (V) at STP V = 1.28E09 / 600 = 2.13E06 ft3 (2133333 ft3 acceptable with rounding)
3.3 * Calculate maximum hydrogen vent volume (M) M = (3% - 1.8%) x 2.13E06 / 100% = 25560 ft3 (25500 to 25600 ft3 acceptable band)
4.1 Record RCS pressure from step 1.3 Records 1200 psig
4.2 Record calculated maximum vent volume (M) from step 3.3 Records M = 25560 ft3
4.3 * Determine hydrogen vent flow rate from Figure 1 at 1200 psig Using Figure 1, determines Hydrogen Flow Rate of 2500 cfm (+/- 100 cfm readability allowance)
4.4 * Calculate maximum vent time (Tv) Tv = 25560 / 2500 = 10.2 mins (+/- 1.0 mins; 9.2 - 11.2 mins acceptable)
Key Decision Point:
Steps 4.3 and 4.4 are the discriminating steps. The applicant must correctly read the Hydrogen Flow Rate from Figure 1 at 1200 psig RCS pressure (2500 cfm). The graph has readability challenges, so a +/- 100 cfm allowance is factored into the acceptable vent time band. The V calculation formula in this revision uses V = 1.28E09 / Tabs (differs from the 2022 version which uses V = 2.62E06 x Tfact). Due to rounding in intermediate steps, the acceptable vent time band is wide (9.2 - 11.2 mins). Rounding should only be applied to the nearest tenths at the final vent time calculation.
Ref: 2-EOP-FRCI-3 (Rev 30) | Task: N1150880502 | K/A: G2.1.25 — Ability to interpret reference materials, such as graphs, curves, tables | Source: New (Rev 01) | View JPM PDF