Exams > 2019 JPM RO-A2 — Perform Borated Water Source Surveillance

2019 JPM RO-A2 — Perform Borated Water Source Surveillance

⚠️ DRAFT
JPM RO-A2 — Perform Borated Water Source Surveillance Admin | RO/SRO | G2.2.37 (3.6)
Location: Classroom
Time-Critical: No
Alternate Path: No
Estimated Time: 10 minutes

Initial Conditions:
- Salem Unit 2 is at 100% power.
- 21 BAT pump developed a leak that went unnoticed until the cross-connected BASTs reached their low level alarm setpoint.
- 21 BAT pump and the leak are isolated. BAST levels are stable.
- 21 BAST level: 48.0%
- 22 BAST level: 48.0%
- 21 BAST temp: 100 F
- 22 BAST temp: 98.1 F
- RWST temperature: 70 F
- RWST levels are: CH II = 41.4, CH III = 41.4, CH IV = 41.4
- Chemistry reports current RWST and BAST boron concentrations are:
  - 21 BAST: 6650 ppm
  - 22 BAST: 6650 ppm
  - RWST: 2350 ppm

Initiating Cue:
- You are the Reactor Operator.
- Perform S2.OP-ST.CVC-0010, Borated Water Sources.
- All Prerequisites are completed SAT.
- Based on the Test Results is the surveillance SAT or UNSAT? (circle one)
Task Standard:
Correctly completes Attachment 2 of S2.OP-ST.CVC-0010 and determines Test Results for combined BAST Volume is UNSAT.
▶ Show Critical Steps & Key Actions
Step Critical Element Standard
3.0 Read and initial Precautions and Limitations Operator reads and initials steps
Att 2 * Record RWST level and verify acceptance criteria Records RWST level from initial cue sheet. Determines Test Results is SAT (364500 to 400000 gals / 40.5 ft to 41.9 ft)
Att 2 * Record RWST temperature and verify acceptance criteria Records 70 F. Determines Test Results is SAT (≥35 F)
Att 2 * Record RWST boron concentration and verify acceptance criteria Records 2350 ppm. Determines Test Results is SAT (≥2300 and ≤2500 ppm)
Att 2 * Record combined BAST volume and verify against TS 3.1.2.6 Figure 3.1-2 Calculates combined BAST level of 96% (48% + 48%). Using Figure 3.1-2, determines required BAST level is >96.5%. Test Results is UNSAT (96% < 96.5% required).
Att 2 * Record BAST temperature and verify acceptance criteria Records temperatures (100 F and 98.1 F). Determines Test Results is SAT (≥63 F)
Att 2 * Record BAST boron concentration and verify against TS 3.1.2.6 Figure 3.1-2 Records 6650 ppm for both BASTs. Using current BAST level of 96% and Figure 3.1-2, determines required concentration is >6650 ppm (~6675 ppm). Test Results is UNSAT (6650 ppm < ~6675 ppm required).
5.3 * Determine overall surveillance result Determines surveillance is UNSAT based on BAST volume and concentration results
Key Decision Point:
The discriminating steps are the BAST volume and concentration checks using TS 3.1.2.6 Figure 3.1-2. The combined BAST level is 96% (48% + 48%), and the applicant must use the figure to determine that the required level at the given boron concentration is >96.5% — making the volume UNSAT by a very narrow margin. Similarly, the boron concentration of 6650 ppm is right at the border of the required concentration from Figure 3.1-2, which shows ~6675 ppm required at 96% level — also UNSAT. The narrow margins are designed to test whether the applicant can correctly read the figure and compare values precisely rather than rounding favorably.
Ref: S2.OP-ST.CVC-0010 (Rev 10) | Task: N0040420201 | K/A: G2.2.37 — Ability to determine operability and/or availability of safety related equipment | Source: New (Rev 01) | View JPM PDF