Q30 — CVCS CV71 Post-SI
004000G2.1.28 (4.1)
Given:
• A Unit 2 Pressurizer Safety Valve has failed open.
• A Reactor Trip and Safety Injection (SI) have automatically actuated.
The Reactor Operator is throttling closed on 2CV71, Seal Pressure Control Valve.
What is the effect on Charging Pump discharge pressure and charging flow to the RCS?
Charging Pump discharge pressure will...
• A Unit 2 Pressurizer Safety Valve has failed open.
• A Reactor Trip and Safety Injection (SI) have automatically actuated.
The Reactor Operator is throttling closed on 2CV71, Seal Pressure Control Valve.
What is the effect on Charging Pump discharge pressure and charging flow to the RCS?
Charging Pump discharge pressure will...
A. rise and total Charging flow will remain constant.
B. rise and total Charging flow will lower.
C. remain constant and RCP Seal Injection flow will rise.
D. remain constant and Charging flow will remain constant.
▶ Show Answer & Explanation
✓ D. Correct. CV-68 & 69, Charging Header Isolation Valves go closed on an SI signal and are in series with the CV-71 flow path, therefore no change to charging pump discharge pressure or flow occur.
✗ A. Plausible because during normal power alignment, throttling the CV-71 will result in a rise in charging discharge pressure and total charging flow will remain constant. Flow will increase to the RCP seals, while charging flow to the regenerative heat exchanger will lower. Incorrect because CV-68 & 69, Charging Header Isolation Valves go closed on an SI signal and are in series with the CV-71 flow path. The second part is correct, total charging flow will remain constant.
✗ B. Plausible because during normal power alignment, throttling the CV-71 will result in a rise in charging discharge pressure. Additionally the candidate may confuse total charging flow with charging flow to the regenerative heat exchanger which will lower. Incorrect because CV-68 & 69, Charging Header Isolation Valves go closed on an SI signal and are in series with the CV-71 flow path.
✗ C. The first part is correct, charging discharge pressure will remain constant as the CV-68 & 69, Charging Header Isolation Valves go closed on an SI signal and are in series with the CV-71 flow path. The second part is plausible because during a normal power alignment, closing down on the CV-71 would increase seal injection flow.
Ref: NOS05CVCS00-17 lesson plan | LO: NOS05CVCS00-17, ELO 4.a | Source: Bank — Salem Vision Database | Cognitive: Comprehension
Connections
- Related systems: CVCS, ECCS
- Related exam: 2020 NRC Written Exam