Q59 — Containment Ventilation Isolation 029000K1.03 (3.6)
1. MANUALLY initiating which of the following from the Control Room Console will also result in a Containment Ventilation Isolation signal?

2. Which valves receive a closed demand from the Containment Ventilation Isolation signal?
A. _(1)_ Phase B and Spray Actuation
_(2)_ VC1, 4 Only
B. _(1)_ Phase A Isolation
_(2)_ VC1, 4 Only
C. _(1)_ Phase A Isolation
_(2)_ VC1, 4, 5, and 6
D. _(1)_ Phase B and Spray Actuation
_(2)_ VC1, 4, 5, and 6
▶ Show Answer & Explanation
✓ D. Correct. The Phase B and Spray Actuation pushbuttons / keys also actuate Containment Ventilation Isolation. The signal goes to all the purge and pressure/vacuum relief valves. See drawing 221057.
✗ A. Incorrect. The first part is correct, the Phase B and Spray Actuation pushbuttons / keys also actuate Containment Ventilation Isolation. The second part is plausible because the candidate may believe that the signal only sends a closed signal to the purge isolation valves. Incorrect as the signal goes to all the purge and pressure/vacuum relief valves.
✗ B. Incorrect. Plausible because the student may believe that a Containment Phase "A" Isolation signal would also cause a Containment Ventilation Isolation. The second part is plausible because the candidate may believe that the signal only sends a closed signal to the purge isolation valves. Incorrect as the signal goes to all the purge and pressure/vacuum relief valves.
✗ C. Incorrect. Plausible because the student may believe that a Containment Phase "A" Isolation signal would also cause a Containment Ventilation Isolation. The second part is correct.
Ref: Safeguards Action Signals, Logic Diagram Sheet 8, drawing 221057 | LO: N/A | Source: Bank, Salem Vision Database | Cognitive: Fundamental