Q70 — Red Blocking Tag Emergency Repositioning
G2.2.13 (4.1)
In an emergency, which position has the authority to authorize the repositioning of a component with a Red Blocking Tag attached?
A. Shift Manager
B. Control Room Supervisor
C. Senior Director of Operations
D. Shift Operations Manager
▶ Show Answer & Explanation
✓ A. Correct. IAW OP-AA-109-115, Attachment 3, Tagging Rules, in an emergency, the Shift Manager can authorize the repositioning of a RBT component if it presents an immediate challenge to safety or personnel or plant equipment.
✗ B. Plausible because CRS do authorization to approve tagouts and releases.
✗ C. Plausible because the applicant may believe that a higher level in the operations organization is needed to perform such an action with repositioning of a RBT.
✗ D. Plausible because the applicant may believe that a higher level in the operations organization is needed to perform such an action with repositioning of a RBT.
Ref: OP-AA-109-115 (R15) | LO: NOS05CONDOP-14, Obj 5 — Describe requirements for Control Room or Field Activities: Industrial Safety Practices | Source: New | Cognitive: Fundamental/Memory
Connections
- Related admin: OP-AA-109-115 — Equipment Tagging
- Related exam: 2022 NRC Written Exam