Exams > 2023 JPM IP-k — Perform a Radioactive Waste Gas Release

2023 JPM IP-k — Perform a Radioactive Waste Gas Release

⚠️ DRAFT
JPM IP-k — Perform a Radioactive Waste Gas Release In-Plant | RO/SRO | 071 A1.03 (2.6)
Location: In-Plant — 64 ft. Elevation, Unit 2 Auxiliary Building (RCA entry required)
Time-Critical: No
Alternate Path: No
Estimated Time: 20 minutes

Initial Conditions:
- Both Salem Units are operating at 100% power
- 21 Waste Gas Decay Tank is in Standby at 90 psig
- 22 Waste Gas Decay Tank is in Holdup at 15 psig
- 23 Waste Gas Decay Tank is O/S at 15 psig
- 24 Waste Gas Decay Tank is O/S at 15 psig
- 2R41 Plant Vent radiation monitor is OPERABLE
- Plant vent flow rate and sample flow rate monitors are OPERABLE

Initiating Cue:
The CRS directs you to RELEASE 21 Waste Gas Decay Tank starting at Step 5.2.11 of S2.OP-SO.WG-0008, 21 Gas Decay Tank to Plant Vent.
- Sections 5.1 and Steps 5.2.1 through 5.2.10 are complete.
Task Standard:
The task is satisfactorily met when the applicant has aligned the release path from 21 Waste Gas Decay Tank (WGDT) IAW step 5.2.11 of S2.OP-SO.WG-0008, released the radioactive gas from 21 WGDT IAW step 5.2.12 of S2.OP-SO.WG-0008, and upon REACHING 10 PSIG, terminates the release by locally closing the 2WG41 IAW step 5.2.14 of S2.OP-SO.WG-0008.
▶ Show Critical Steps & Key Actions
Step Critical Element Standard
5.2.11.A ENSURE 21 GDT is NOT in service Verifies 21 GDT is NOT in service.
5.2.11.B ENSURE 21 GDT is NOT selected for "Standby" Verifies 21 GDT is NOT selected for STANDBY.
5.2.11.C RECORD 21 GDT "Initial Pressure" (PIS1036) on Attachment 3 Records 21 GDT pressure (PIS1036) as 90 psig.
5.2.11.D.1 * TURN 2WG41 Waste Gas Vent Valve Flow Bias fully counterclockwise until indicator <0% Simulates turning the Flow Bias knob fully COUNTER-CLOCKWISE until indicator is less than 0%. Must set bias to <0% before opening to latch and set the valve.
5.2.11.D.2 * POSITION 2WG41 Selector Switch to OPEN AND RELEASE to AUTO position (spring return) Simulates positioning 2WG41-SWT (local control switch at 104-2 panel) to OPEN, then releases to AUTO.
5.2.11.D.3 * TURN 2WG41 Waste Gas Vent Valve Flow Bias clockwise until indicator >=100% Simulates turning 2WG41 flow bias CLOCKWISE until indicator reads >=100%. 2WG41 will not fully open until flow bias is adjusted to 100%.
5.2.11.D.4 ENSURE with Unit 2 Control Room that 2WG41 has lost CLOSED indication AND audible alarm received Calls Control Room to verify 2WG41 has lost closed indication and audible alarm was received.
5.2.11.D.5 * TURN 2WG41 Waste Gas Vent Valve Flow Bias fully counterclockwise until indicator <0% Simulates turning 2WG41 flow bias COUNTER-CLOCKWISE until indicator reads <0%.
5.2.11.D.6 ENSURE with Unit 2 Control Room that 2WG41 has closed indication Calls Control Room to verify 2WG41 has CLOSED indication.
5.2.11.D.7 * POSITION 2WG41 Selector Switch to CLOSE Simulates positioning 2WG41 selector switch to CLOSE.
5.2.11.E PERFORM Independent Verification of 2WG41 Flow Bias position, RECORD on Attachment 1, Section 2.0 Requests another operator perform IV of the 2WG41 Waste Gas Vent Valve Flow Bias position.
5.2.11.F * OPEN 21WG31, GDT INLET VALVE Simulates rotating valve COUNTER-CLOCKWISE to open 21WG31.
5.2.11.G * Slowly OPEN 21WG34 Simulates slowly rotating COUNTER-CLOCKWISE to open 21WG34.
5.2.11.H RECORD IV of 21 GDT discharge valves 21WG31 and 21WG34 on Attachment 1, Section 3.0 Requests IV of 21 GDT discharge valves prior to commencing release.
5.2.12.A * POSITION 2WG41 Selector Switch to OPEN AND RELEASE to AUTO (spring return) Simulates rotating selector switch to OPEN and then releasing to AUTO to commence the release.
5.2.12.B * SLOWLY SET 2WG41 Waste Gas Vent Valve Flow Bias to <=100% (max release rate 32 SCFM) Simulates adjusting 2WG41 Waste Gas Vent Valve Flow Bias to <=100%, which corresponds to a maximum release rate of 32 SCFM.
5.2.12.C PERFORM IV of 2WG41 Flow Bias positioning on Attachment 1, Section 4.0 Requests IV on 2WG41 flow bias position.
5.2.12.D RECORD In Progress Release Data on Attachment 2, Section 5.1 Records data on Attachment 2.
5.2.13.B RECORD Meteorological Data in Attachment 2, Section 5.2 from SPDS screenshot Records MET Data from SPDS screenshot. If Met Monitor NOT OPERABLE, notify SM/CRS per UFSAR 7.7.2.12.
5.2.14.A * TURN 2WG41 Flow Bias fully counter-clockwise until indicator is <0% Simulates adjusting Flow Bias fully COUNTER-CLOCKWISE until indicator is <0% to secure the release.
5.2.14.B * PLACE 2WG41-SWT in CLOSE position, AND ENSURE 2WG41 is CLOSED Simulates placing switch 2WG41-SWT in CLOSED position and verifies 2WG41 is CLOSED.
5.2.14.C * CLOSE 21WG34 Simulates closing 21WG34 by turning valve in CLOCKWISE direction.
5.2.14.D RECORD Final Release Data in Attachment 2, Section 5.3 Records final release data.
Key Decision Point:
The latch-and-set sequence (Step 5.2.11.D) is the most complex portion — the applicant must correctly manipulate the 2WG41 Flow Bias and Selector Switch in the proper order (bias to <0%, open to auto, bias to 100%, verify lost closed indication, bias back to <0%, verify closed, then position selector to CLOSE). Then for the actual release (Step 5.2.12), the applicant must open 2WG41 to AUTO and set flow bias to <=100% (max 32 SCFM). Upon reaching 10 psig, the release is terminated by reducing flow bias to <0%, closing 2WG41-SWT, and closing 21WG34.
Ref: S2.OP-SO.WG-0008 (R27) | Task: N0715070104 | K/A: 071 A1.03 — Ability to predict and/or monitor changes in parameters associated with operation of the Waste Gas Disposal System, including: Holdup tank pressure and level | Source: Bank | View JPM PDF