2023 JPM RO-A1.b — Determine Time to Makeup to Unit 2 RWST

⚠️ DRAFT
JPM RO-A1.b — Determine Time to Makeup to Unit 2 RWST Admin | RO/SRO | G2.1.23 (4.3/4.4)
Location: Classroom (Administrative)
Time-Critical: No
Alternate Path: No
Estimated Time: 15 minutes

Initial Conditions:
- Salem Unit 2 is at 100% power
- You are the RO on-shift
- Make-up to the RWST is required to restore level to the Tech Spec minimum
- Current RWST level is 40.0 feet
- Current RWST boron concentration is 2360 ppm
- Current BAST boron concentration is 6900 ppm
- Section 5.8.3 of S2.OP-SO.CVC-0006, Boron Concentration Control, will be used to make-up to the RWST

Initiating Cue:
The CRS directs you to perform the following:
1. DETERMINE the boric acid flowrate to make-up to the RWST
2. DETERMINE the time to raise the RWST to the Tech Spec minimum level
Task Standard:
The task is satisfactorily met when the applicant has determined a boric acid flowrate of 26 gpm and will take 59.2 minutes to raise the RWST level to the Tech Spec minimum level.
▶ Show Critical Steps & Key Actions
Step Critical Element Standard
1.0 * Determine boric acid flowrate Per step 5.8.3.A, obtain boric flow setpoint from S2.RE-RA.ZZ-0012, Figures 100B or 100D. Determines a boric acid flowrate of 26 gpm.
2.0 * Determine RWST Tech Spec minimum level Per TS 3.5.4, determines the RWST minimum level is 40.5 feet (363280 gallons).
3.0 * Determines the amount of make-up (in gallons) required to raise RWST level from 40.0 feet to Tech Spec minimum level (40.5 feet) Using Tank Curves for Unit 2 RWST: 40.0 feet = 360000 gallons, 40.5 feet = 364500 gallons. 364500 - 360000 = 4500 gallons.
4.0 * Determine the amount of time to raise RWST level to the Tech Spec minimum level Determines it will take 59.2 minutes: (4500 gallons / 76 gpm = 59.2 minutes). 76 gpm = 26 gpm boric acid + 50 gpm primary water.
Key Decision Point:
The calculation chain: (1) look up boric acid flow from REM figures based on RWST and BAST boron concentrations → 26 gpm, (2) find TS minimum RWST level → 40.5 feet, (3) convert feet to gallons using tank curves → 4500 gallons needed, (4) total makeup flow = boric acid + primary water (26 + 50 = 76 gpm), (5) time = 4500/76 = 59.2 minutes.
Ref: S2.OP-SO.CVC-0006, S2.RE-RA.ZZ-0012, S2.OP-TM.ZZ-0002 | Task: N0040170101 | K/A: G2.1.23 — Ability to perform general and/or normal operating procedures during any plant condition | Source: New | View JPM PDF