Q82 — IR NIS P-6 Permissive / TS Bases
T1G2 APE 33 AA2.01 (3.4)
Given:
• Salem Unit 2 is performing a reactor startup
• A valid P-6 permissive light is now LIT on 2RP4
When the P-6 permissive was LIT, the RO observed the following:
• 2N35, Intermediate Range, NIS channel indicates 1E-5% power
• 2N36, Intermediate Range, NIS channel indicates 1E-8% power
Which of the following completes both statements?
1. The (1) Intermediate Range (IR) NIS channel is not indicating as expected and is INOPERABLE.
2. Per TS 3.3.1.1 Instrumentation Bases, why is the 24 hour action time allowed when one IR NIS channel is INOPERABLE?
• Salem Unit 2 is performing a reactor startup
• A valid P-6 permissive light is now LIT on 2RP4
When the P-6 permissive was LIT, the RO observed the following:
• 2N35, Intermediate Range, NIS channel indicates 1E-5% power
• 2N36, Intermediate Range, NIS channel indicates 1E-8% power
Which of the following completes both statements?
1. The (1) Intermediate Range (IR) NIS channel is not indicating as expected and is INOPERABLE.
2. Per TS 3.3.1.1 Instrumentation Bases, why is the 24 hour action time allowed when one IR NIS channel is INOPERABLE?
A. (1) 2N35 — (2) Takes into account the low probability of failure of the operable IR channel during this period.
B. (1) 2N35 — (2) Takes into account the low probability of reactivity events during this period.
C. (1) 2N36 — (2) Takes into account the low probability of reactivity events during this period.
D. (1) 2N36 — (2) Takes into account the low probability of failure of the operable IR channel during this period.
▶ Show Answer & Explanation
✓ D. Correct. When P-6 is LIT, the IR NIS would indicate 1E-5% power. Therefore, 2N36 IR channel is not indicating for the expected overlap between the SR channels. Per TS 3.3.1.1 bases, the IR NIS channel high flux trip ensures that protection is provided against an uncontrolled RCCA bank rod withdrawal accident from a subcritical condition during startup. The trip function provides redundant protection to the Power Range High Flux - Low Setpoint trip function. The 24 hour action times for one inoperable IR channel allow for a slow and controlled adjustment above P-10 or below P-6 and take into account the redundant capability afforded by the operable IR channel and its low probability of failure during this period.
✗ A. Part 1 is incorrect. Plausible because the operator can incorrectly recall the point where the SR and IR overlap when P-6 is present. Part 2 is correct.
✗ B. Part 1 is incorrect. Plausible because the operator can incorrectly recall the point where the SR and IR overlap when P-6 is present. Part 2 is incorrect. Plausible because the IR channel does provide redundant trip function to the PR NIS low setting trip, but this is not the bases for the 24 hour action limit.
✗ C. Part 1 is correct. Part 2 is incorrect. Plausible because the IR channel does provide redundant trip function to the PR NIS low setting trip, but this is not the bases for the 24 hour action limit.
Ref: TS 3.3.1.1 bases | LO: NOS05ABNIS1-04, Obj 2 — Describe, in general terms, the actions taken in S2.OP-AB.NIS-0001(Q) and their Bases | Source: New | Cognitive: Comprehension/Analysis